Galaxy Digi Telecoms Connections and Configuration
To install the Galaxy for full remote management you will require the Dial Capture Module (DCM).
Connect the WebWay Dial Capture Module (DCM) panel interface A and B to the Galaxy Line A and B terminals on
either the Galaxy Internal or External Dialler module.
Connect the WebWay PWR + and - to the GND and +12V terminals on the Galaxy Panel.
Galaxy External Telecoms panel configuration
Go to Menu 56
Select Internal Telecoms (Option 1) or External Telecoms (Option 5) depending on how you’ve connected the
WebWay SPT.
Select Format (Option 1)
Enter SIA (Option 2), <Level 3(0-4)>
Press Enter
Under the trigger events settings you define which events the panel will report.
Note: it is recommended that the additional Triggers are selected:
Select 10 – Settings <ON> (Default OFF)
Select 18 – Zone Restorals <ON> (Default OFF)
Select Tel No. 1 (Option 2)
Set Phone Number – 01234 567890 (any valid phone number is acceptable)
Select Account number (Option 3)
Enter <_______> (Site ID)
Go to Remote Access (Option 12)
Select Access Period <Anytime>
Select Mode <Direct Access>
NOTE – in this integration the SPT is not emulating a Honeywell Communications module, but a Digi device normally
used to transmit alarms. This method of integration may be used when the panel firmware is below V1.40. However there
are limitations in the SIA events the panel can generate and the use of PIN alarms in conjunction with the serial interface
may be required.