GE Aritech CD95 alarm panel connections and configuration
To install the Aritech CD95 for full remote management you will the Dial Capture Module (DCM).
Connect the WebWay DCM panel interface A and B to the A and B terminals of the RD6203 digital communicator.
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
It is recommended that the dialler is defaulted before applying these settings:
Aritech CD95 panel configuration
Enter engineering mode and enter Digi Code password
Go to menu 1 - Tel/account numbers
Enter telephone number <01234 567890> (any valid phone number is acceptable)
Enter account number <_ _ _ _ _ _>
Select Protocol CSI <X SIA>
Select U/D Frequency <CCITT>
Enter U/D telephone number <123456>
Enter U/D account number <_ _ _ _ _ _>
Select U/D initiated by PC calls – <Yes)>; User Code – <Yes>; On line – <Yes>
Select U/D if armed <Yes>
Enter Answer PC rings value <1>
Go to menu 2 – Dial Options
Select Dialling <DTMF>
Select dial tone type <UK>
Select Wait dial tone <No>
Select Call interval <60>
Select Retry period <120>
Select Calls for FTC <03>
Go to Menu 3 - report options and programme the events required
Go to Menu 5 - Protocol Options
Select <SIA>
Select 1 event per call <Yes>
Select 1 account per call <Yes>
Select <3 Dig. Event No.>
Select SIA Freq. <Bell>