Castle CareTech alarm panels
EuroONE
EuroONE Plus
Serial interface connection
Connect the RS232; R &T terminals and RTN on the WebWay to the MSX-5 Expansion Card that should be located in
the Expansion Card slot on the Euro-ONE and Euro-ONE Plus panel. The connector is not labeled, however the
connections are from right to left PIN 1 Black, PIN 2 White, PIN 3 Red. WebWay connections are PIN T White, PIN R
Red and RTN Black.
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
EuroONE alarm panel configuration - serial mode
Go to Engineering Mode
Go to programme Digi/SMS calls
Select Disable Digi/SMS <0>
Select ARC Details <1>
Select Active <Yes>
Select format <WebWayOne IP> (Option 141)
Select SIA Ack Char <006>
Select SIA Nack Char <021>
Select valid areas <select areas to be reported>
Select stop on success <yes>
Select ARC account <No>
Select content 1-16 <Trigger events> (recommend 1-5, and 7-13)
Select content 17-32 <Trigger events> (recommend 21-25, 27-30, and 32)
Select redials <03>
Select time out <15>
Select test calls <No>
Note: The recommended Content settings will send the most relevant event reports. Some installations may require less
event types to be activated. Refer to the Castle documentation for more information.
Go to ‘set up downloading’
Select download by <IP>
Select poll timeout <10>