WEBWAYONE LTD, Unit 11 Kingfisher Court
Hambridge Road, Newbury, Berkshire. RG14 5SJ
00 44 1635 231 514 support@webwayone.co.uk
GE Aritech CD MPI232 series alarm panel connections and configuration using
the WebWay RS232 interface
The CD panel will require the MPI232 serial interface module
Connections:
PWR + = Any relevant +12V or +24V terminal
PWR - = Any relevant ground (OV)
232 T = Blue
232 R = Red
RTN = Green
To achieve a connection to the MPI232 serial interface an additional serial cable is required, part number 05 5017.
WebWay SPT requirements:
The communicator must be running V3.41 firmware or higher
Panel type to set = CDMPI Menu 9 Option ?
MPI232 panel configuration
To access the MPI232 settings connect a PC to the MPI232's DTE serial port.
Run up a hyperterminal application set at 9600, None, 8, 1.
Set switch 3 on the MPI232 module to OFF.
Power up MPI232 module.
You will see the following:
MPI V2.23 programming main menu
===============================
1. Central station menu
2. Report options
3. Protocol options
0. Exit MPI programming
Make your choice:
Select 3: Protocol options