Cooper Menvier alarm panel connections and configuration
Cooper Menvier M Series M1000, M2000
The M Series main board assembly has a 9 way D-type connector at the top right. This connects to the R, T and RTN
terminals of the WebWayOne panel interface. The connection details are as follows:
9 way D-type WebWayOne 2424
2 T (Blue) 232
3 R (Red) 232
5 RTN (Green)
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
Go to menu 2-5-2 Communications 2 Digicom ARC No 1
Select telephone number <01234 567890> (any valid phone number is acceptable)
Select account number <______>
Select dialling mode <consecutive>
Select restore signals <enable>
Select FF channels <8FF channels>
Select CID/SIA reports <Full>
Go to menu 2-5-4 Communications 4 RS232 options
Select RS232 baud <38400>
Select remote modem <enable>
Go to menu 2.5.1 Communications 1 downloader
Select Password <______> (same as configured in downloader application)
Select site ID <______> (same as configured in downloader application)
Select access mode <unattended>
Select edit call Nos <not configured>
Select rings to answer <immediate>
Select baud rate <1200>
Select 51:Downloader - Modem options - Ans Phone Defeat <Disabled>